Antunes, AJ SE-4200/4400 사용자 설명서

다운로드
페이지 24
SE-4200/4400 WATER FILTRATION SYSTEM
10
P/N 1010852 Rev. C 04/06
OPERATION
Filtration Process
The filtration process includes a Filtration Cycle and a 
Backwash Cycle.
During the Filtration Cycle, water enters the system 
inlet port and passes through the filter elements before 
exiting via the Permeate outlet.  
This system is designed so that no valves are powered 
during the Filtration Cycle.  This allows water to contin-
ue to be filtered during a power outage and it minimizes 
electrical power consumption.
After a period of time, the filters have to be cleaned.  
This is accomplished through the Backwash Cycle.  
During the Backwash Cycle, filtered water from one of 
the cartridges is fed back through the other cartridge to 
break up any debris collected on the membrane walls.  
The Backwash Cycle includes a forward flush step 
which then uses the feed water to flush away the loos-
ened debris from the cartridge’s membranes.  The 
valves are only powered during the flushing cycle and 
in STOP MODE.
NOTE:  Both the Filtration and Backwash cycles 
can be completely automated through the Control 
Panel.  See the Programming section within this 
manual.
Control 
Button
Function
FLUSH
Performs a QUICK FLUSH operation 
when actuated during FILTER MODE or 
STOP MODE.  
RUN
Initializes and starts an internal timer for 
the automatic flushing of the system and 
puts the system into FILTER MODE.  
When pressed, the system performs a 
BORE AIR RELEASE operation before 
entering FILTER MODE.
STOP
Stops all functions immediately; pow-
ers all valves.  Closes the Input and 
Permeate ports/valves and opens all 
Drain ports/valves.
F1
Starts the Backwash Cycle during 
FILTER MODE or STOP MODE.
F2
Service Feature.  Valve, Transducer, 
and alarm status can be viewed and 
changed.  Press and hold this button for 
a minimum of 3 seconds to access this 
mode.
CURSOR
Up/Down/Left/Right arrow buttons 
are used to scroll through the choices 
shown in the Message Display window.
MENU
Allows access to program and setting 
features .
ENTER
Used to confirm settings in MENU 
mode.
Operating Controls (Figure 2)
Message Display
FLUSH
RUN
F1
F2
STOP
MENU
ENTER
Figure 2.  Operating Controls