CAUTION
Water Pressure must not exceed 7 bar (100 psi).  
To reduce water pressure, install a water pressure 
regulator and set water pressure to suit applica-
tion.  Note that the trans membrane pressure 
must be .5 - 3 bar (7.25 - 43.5 psi).
CAUTION
This equipment is to be installed to comply with 
the basic plumbing code of the Building Officials 
and Code Administrators, INC. (BOCA) and the 
Food Service Sanitation Manual of the Food and 
Drug Administration (FDA).
Unpacking
The carton should contain the filtration system and an 
information packet.
 
  •  SE-4200 or SE-4400 
•  Information Packet
  1.  Remove unit and all packing materials from ship-
ping carton.
  2.  Remove all packing materials and protective cov-
erings from the unit.
  2.  Remove the information packet.  To prevent delay 
in obtaining warranty coverage, fill out and mail 
the warranty card.
NOTE:  If any parts are missing or damaged, con-
tact Antunes Filtration Technologies IMMEDIATELY 
at 1-800-253-2991 (toll free in the U.S.) or 630-784-
1000.
Equipment Setup
GENERAL
When placing the unit into service, pay attention to the 
following guidelines.
  •  Make sure power to the unit is off.
  •  Do not immerse the  power cord or plug in water.
  •  Keep power cord away from heated surfaces.
ELECTRICAL
Ensure that the line voltage corresponds to the stated 
voltage on the units specification label.  Make sure 
that the plug on the power cord from the system and 
the outlet match.  For proper operation of the system, 
and to ensure the highest quality of water from the sys-
tem, make sure that the system is not connected to a 
switched electrical outlet.
An ABC-type fuse (6 Amp, 250 VAC) is located inside 
the control box.  
PLUMBING
NOTE: This unit is designed to use tap water not to 
exceed 104º F (40º C).
The SE Series uses the following connections:
  •  Water Inlet (Feed Water) 
3/4” NPT
  •  Permeate (Product Water) 
3/4” NPT
  •  Drain  
3/4” NPT
INSTALLATION
When making a plumbing connection to the system, 
remember to use a back-up wrench on the support 
plumbing.  Always use a good quality and approved 
pipe sealant or Teflon tape on pipe threads.  
Be careful not to get the pipe sealant inside the pipe 
when making the connections.  Do not over tighten the 
connections.  
It is recommended that plastic fittings be used when 
connecting to the plastic connections of the system.  
This will reduce the possibility of cracking the connec-
tions due to over tightening.  If soldered plumbing is 
used, do not apply heat to, or near, the filtration system.  
The use of union (O-ring seal) connections is highly 
recommended for ease of installation and future servic-
ing.
Suggested Tools and Supplies for 
Installation
The following tools and supplies are suggested to make 
the installation easier:
•  Screwdriver 
•  Drill with bits 
•  Strap wrench  
  (up to 6” diameter) 
•  Tape measure 
•  Two gallon bucket 
•  Fresh 5 1/4% liq- 
  uid chlorine bleach 
  (such as Clorox®) 
•  Adjustable wrenches 
•  Pipe wrenches 
•  Level 
•  Pipe dope or Teflon  
  tape