Please note the following:
 
DO NOT install this water heater with iron piping. 
 
The system should be installed only with piping that 
 
is suitable for potable (drinkable) water such as  
 
copper, CPVC, or polyethylene (PEX). 
 
DO NOT use PVC water piping.
 
DO NOT use any pumps, valves, or fi ttings that are  
 
not compatible with potable water.
 
DO NOT use valves that may cause excessive 
 
restriction to water fl ow. Use full-fl ow ball or gate
 valves 
only.
 
DO NOT use tin-lead solder in potable water lines.  
 
Use 95/5 tin antimony or other equivalent material.
 DO 
NOT tamper with the energy smart module,
 
electronic thermostat, temperature sensors, heat- 
 
ing elements, electrical connections, or temperature  
 
and pressure relief valve. Tampering voids all war- 
 
ranties. Only qualifi ed person should service these  
 components.
 DO 
NOT use with piping that has been treated with
 
chromate’s, boiler seal, or other chemicals.
 DO 
NOT add any chemicals to the system piping
 
which will contaminate the potable water supply.
Closed System/Thermal Expansion
Typically, a closed system includes a pressure reducing 
valve (PRV) on the cold water inlet (supply line). As water 
is heated, it expands (thermal expansion). In a closed sys-
tem, the volume of water will grow. As the volume of water 
grows, there will be a corresponding increase in water 
pressure due to thermal expansion. Thermal expansion 
can cause premature tank failure (leakage). This type of 
failure is not covered under the limited warranty. Thermal 
expansion can also cause intermittent temperature-
pressure relief valve operation: water discharged from the 
valve due to excessive pressure build up. The tempera-
ture-pressure relief valve is not intended for the constant 
relief of thermal expansion. This condition is not covered 
under the limited warranty. 
A properly-sized thermal expansion tank should be in-
stalled on all closed systems to control the harmful effects 
of thermal expansion. Contact a plumbing service agency 
or your retail supplier regarding the installation of a ther-
mal expansion tank.
Temperature and Pressure
Relief Valve
Figure 5
Temperature and Pressure
Relief Valve Installation
Optional location some
models only
Temperature and
Pressure Relief Valve
Discharge Line
3/4 inch min.
Do not cap or plug.
6 inch
maximum
Drain  Pan
Drain
GRID
ENABLED
VACATION
STANDARD
ENERGY
SMART
°F/°C
F
For protection against excessive pressures and
temperatures, a temperature and pressure relief valve
must be installed in the opening marked “T&P RELIEF
VALVE” (See Figure 5). This valve must be design certi-
fi ed by a nationally recognized testing laboratory that 
maintains periodic inspection of the production of listed 
equipment or materials as meeting the requirements 
for Relief Valves for Hot Water Supply Systems, ANSI 
Z21.22. The function of the temperature and pressure 
relief valve is to discharge water in large quantities in the 
event of excessive temperature or pressure develop-
ing in the water heater. The valve’s relief pressure must 
not exceed the working pressure of the water heater as 
stated on the rating plate.
IMPORTANT: Only a new temperature and pressure 
relief valve should be used with your water heater. Do 
not use an old or existing valve as it may be damaged or 
not adequate for the working pressure of the new water 
heater. Do not place any valve between the relief valve 
and the tank.
Explosion Hazard
• Temperature-pressure relief 
valve must comply with ANSI 
Z21.22-CSA 4.4 and ASME 
code.
•  Properly sized temperature-
pressure relief valve must be 
installed in opening provided.
•  Can result in overheating 
and excessive tank pressure.
•  Can cause serious injury or 
death.
Expansion Tank Sizing Chart
Inlet         Water Heater Capacity (Gallons)
 Water
   Pressure 
30 
40 
50 
66 
82
Expansion 40psi  2  2 2 5 5
Tank 
50psi  2  2 2 5 5
Capacity  60psi  2  2 5 5 5
Needed  70psi  2  2 5 5 5
   
80psi  2  5 5 5 5
A thermal expansion tank can help prevent damage to the 
water heater and other appliances (i.e.: washing machine, 
ice maker, dishwasher, etc.).
IMPORTANT: Do not plug or remove the temperature and 