Menu Options
3-23
hours or fixture hours.  The procedures below are listed in the order 
that they appear on the menu map.
Viewing the Logic Board Temperature (TEMP)
To view the current logic board temperatures:
1.
Press and hold the <Menu> button until “ADDR” appears on the LED 
display.
2.
Using the <Up> and <Down> arrow buttons, scroll to the “INFO” menu 
and press the <Enter> button to select the “INFO” menu.
3.
Using the <Up> and <Down> arrow buttons, scroll to the “TEMP” option.  
(This will be the first menu displayed.)  Press the <Enter> button to 
select the “TEMP” option.  
4.
The LED will display the temperature of the fixture’s logic board in 
degrees centigrade.
The maximum temperature reading for the logic board is 76° C.  If this 
maximum temperature is exceeded, the fixture’s lamp, LAD, and 
motors will shut down and the LED panel will display “OVER TEMP.”  
Viewing the Current Lamp Hours (L/HR)
To view the number of hours the lamp has been on since this option 
was reset:
1.
Press and hold the <Menu> button until “ADDR” appears on the LED 
display.
2.
Using the <Up> and <Down> arrow buttons, scroll to the “INFO” menu 
and press the <Enter> button to select the “INFO” menu.
3.
Using the <Up> and <Down> arrow buttons, scroll to the “L/HR” option 
and press the <Enter> button to select the “L/HR” option.  The LED will 
display the number of hours the lamp has been on since this option 
was reset.
Viewing the Current Fixture Hours (F/HR)
To view the number of hours the fixture has been on since this option 
was reset:
1.
Press and hold the <Menu> button until “ADDR” appears on the LED 
display.
2.
Using the <Up> and <Down> arrow buttons, scroll to the “INFO” menu 
and press the <Enter> button to select the “INFO” menu.
3.
Using the <Up> and <Down> arrow buttons, scroll to the “F/HR” option 
and press the <Enter> button to select the “F/HR” option.  The LED will 
display the number of hours the fixture has been on since this option 
was reset.