Elica EFG630SM 설치 설명서

다운로드
페이지 41
13
Replacing the light bulb
CAUTION
Before replacing the lamps, switch power off at service panel 
and lock service panel disconnecting means to prevent pow-
er from being switched on accidentally.
NOTE: Turn off the lights and fan. Allow the lights to cool 
before  handling.  If  new  lights  do  not  operate  be  sure 
lights are inserted correctly before calling service.
Replace Lights
Remove the damaged light (twist counter clockwise) and 
replace  with  a  new  120  Volt,  50  Watt  (maximum)  50° 
halogen light made for a GU10 base, 
suitable for use in 
open luminarie.
Charcoal Filter
If the model is not vented to the outside, the air will be recir-
culated through disposable charcoal filters that help remove 
smoke and odors.
The charcoal filters cannot be cleaned.
They must be replaced.
Cover the grill that protects the suction motor with the carbon 
filter so that the slots on the filter correspond to the pins on 
the sides of the motor protection grill.
Turn the carbon filter clockwise to block them (bayonet fix-
ing).
The  charcoal  filters  should  be  replaced  every  4-6  months 
(depending on hood usage).
NOTE: DO NOT rinse, or put charcoal filters in an automatic 
dishwasher.
NOTE: Charcoal filters are not included with the hood.
They must be ordered from your supplier.
Order the needed kit specifying your hood model and width 
size.
A. Charcoal filter
B. Slots
C.Blower motor
A
B
C