Gaggenau AL400721 브로셔
Vario cooktops
125
V G 264 114F
Stainless steel control panel
Width 60 cm
Liquid gas 28 – 37 mbar
Width 60 cm
Liquid gas 28 – 37 mbar
V G 264 214
Stainless steel control panel
Width 60 cm
Natural gas 20 mbar
Width 60 cm
Natural gas 20 mbar
V G 264 134F
Aluminium control panel
Width 60 cm
Liquid gas 28 – 37 mbar
Width 60 cm
Liquid gas 28 – 37 mbar
V G 264 234
Aluminium control panel
Width 60 cm
Natural gas 20 mbar
Width 60 cm
Natural gas 20 mbar
Installation accessories
S H 260 000
S H 260 000
Hinge holder for fitting the appliance
cover
cover
V V 200 014
Stainless steel connection strip for
combination with further Vario
cooktops
combination with further Vario
cooktops
V V 200 034
Aluminium connection strip for
combination with further Vario
cooktops
combination with further Vario
cooktops
Special accessories
V D 201 014
V D 201 014
Brushed stainless steel appliance
cover (order two covers)
cover (order two covers)
V D 201 034
Shot-blasted aluminium appliance
cover (order two covers)
cover (order two covers)
Vario gas cooktop 200 series
V G 264
– Can be combined with the
cooktops of the Vario 200 series to
a harmonic unity
a harmonic unity
– Generous control panel for comfort-
able and secure operation
– Solid smooth-surface cast pan
supports for easy and safe
positioning of cookware
positioning of cookware
– 9.4 KW on 4 burners
Cooking zones
2 high output burners (560 – 2,800 W),
suitable for pots up to max. ø 22 cm.
2 standard burners (380 – 1,900 W),
suitable for pots up to max. ø 22 cm.
suitable for pots up to max. ø 22 cm.
2 standard burners (380 – 1,900 W),
suitable for pots up to max. ø 22 cm.
Handling
Control knobs with cooking zone and
output level markings.
One-handed operation.
Electric ignition.
Gas valve with fine control.
output level markings.
One-handed operation.
Electric ignition.
Gas valve with fine control.
Features
Two-part cast pan support with
continuous pot surface.
Enamelled burner cover.
continuous pot surface.
Enamelled burner cover.
Safety
Thermoelectric safety pilot.
Planning notes
Special nozzles can be ordered as
spare parts.
Air intake from above.
No intermediate shelf required.
Appliance can be snapped into the
worktop from above.
Securing rail on the rear and the front.
A minimum lateral clearance of at least
150 mm from adjacent heat-sensitive
furniture or contact surfaces must be
observed or thermal insulation fitted.
With a total connected load of more
than 12 kW local regulations
concerning room ventilation, room size
and combination of extraction or
recirculation hoods must be observed.
Minimum clearance between gas
cooktop(s) with more than 12 kW and
ventilation hood 70 cm.
spare parts.
Air intake from above.
No intermediate shelf required.
Appliance can be snapped into the
worktop from above.
Securing rail on the rear and the front.
A minimum lateral clearance of at least
150 mm from adjacent heat-sensitive
furniture or contact surfaces must be
observed or thermal insulation fitted.
With a total connected load of more
than 12 kW local regulations
concerning room ventilation, room size
and combination of extraction or
recirculation hoods must be observed.
Minimum clearance between gas
cooktop(s) with more than 12 kW and
ventilation hood 70 cm.
Special nozzles (order 2 of each):
Part No. 433603 Natural gas 20 mbar
Part No. 419831 Liquid gas 30 mbar
Part No. 419830 Liquid gas 50 mbar
Part No. 433603 Natural gas 20 mbar
Part No. 419831 Liquid gas 30 mbar
Part No. 419830 Liquid gas 50 mbar
Connection
Total connected load gas 9.4 kW .
Total connected load electric 1.0 W .
Connecting cable 1.4 m with plug.
Total connected load electric 1.0 W .
Connecting cable 1.4 m with plug.