Hearth & Home Technologies MBK 사용자 설명서

다운로드
페이지 32
R
Page 14
   7004-187F  September 1, 2008
Yosemite Wood Stove
6
Support Plate & Clamp
Listed Rigid
Stainless Liner
Stainless Steel
Flex Section
Stainless 
Connector 
Pipe
Carry Stovepipe
Above the Liner
Damper Plate is 
Removed or 
Fastened in Open 
Position
Use Damper Adapter or 
Seal With Sheetmetal 
and Sealant
Cleanout
Stainless Tee with Cleanout
Fireclay liner 5/8" 
(16mm) Minimum or 
Equivalent.
Heat Shield
First, make the frame for the thimble, ensuring it is no smaller 
than 14 inches (356mm) square to maintain a 2 inch (51mm) 
air space around the chimney section.  
Attach the wall spacer to the chimney side of the frame.  
Then insert the frame into the opening, toe nailing it to the 
wall studs.  Install the wall band in the framing to secure the 
chimney section in place.  
Insert a single section of chimney connector into the chimney 
through the wall band, being sure it does not protrude into the 
chimney beyond the edge of the chimney flue lining.  
Apply high temperature furnace cement to the end of the 
chimney section and install it over the connector, through the 
wall spacer.  Tighten the wall band to hold the chimney section 
firmly in place and against the chimney.  
Install the trim collar on the outside of the opening.  A 1 inch 
(25mm) air space between the connector and the chimney 
section must be maintained.  
During installation a 2 inch (51mm) air space to the wood 
framing is maintained.  Do not fill this space with insulation.  
Insulation in this air space will cause a heat buildup which 
may ignite the wood framing.
SOLID PACK CHIMNEY WITH METAL 
SUPPORTS AS A THIMBLE (CONT'D)
Chimney Flue 
Liner
Fireclay 
Liner or 
Equivalent
Masonry Chimney 
Constructed to NFPA 211
Wall Spacer
Wall Band
Trim Collar
Chimney
 Connector
1" (25mm) Air 
Space to Chimney 
Section
Min. Clearance 
2" (51mm)
Min. Chimney Clearance 
to Wall Spacer and 
Combustibles - 2" (51mm)
Chimney Section
Trim Collar
Chimney Section 
with 2" (51mm) 
Clearance to 
Combustibles
Chimney 
Connector
Fire Clay 
Flue Liner
with Airspace
Masonry
 Chimney
Wall Band to 
Secure 
Chimney 
Section
Wood Studs Used for 
Framing - Spaced 2" 
(51mm) clearance 
from Masonry 
Wall Spacer
Figure 14A
CONNECTION TO A MASONRY 
FIREPLACE
There are several kits available to connect the stove to 
a masonry fireplace.  Look for a listed kit.  The kit is an 
adapter which is installed at the location of the fireplace 
damper.  The existing damper may have to be removed to 
allow installation of the kit. 
The key points of this type of stove connection are: 1) that 
the connector pipe must extend up the chimney above where 
the fire clay liner starts, and 2) the areas of the kit installation 
and penetration should fit tightly and be sealed with high 
temperature furnace cement unless the kit’s instructions state 
otherwise.  (See Figure 14C).  The tight fitting installation 
aids the proper draw of the chimney.
Horizontal Flue Heat Shield, Accessory 
Part HTSHLD-7006 is required for rear vent 
installations.
Figure 14B
Figure 14C