Chateau™ Decorative Gas Appliance
20009543
Top of Unit to Ceiling ................................ 36” (914 mm)
Front of Unit to Combustibles 
(both sides)
 ... 36” (914 mm)
Appliance
  Top Standoffs .............................................. 0” (0 mm)
  Bottom ......................................................... 0” (0 mm)
  Side Standoffs ............................................. 0” (0 mm)
  Back Standoffs ............................................ 0” (0 mm)
Venting
  Horizontal Termination through-a-side wall:
    Vertical Sections:
      Sides ................................................ 2¹⁄₂” (64 mm)
    Horizontal Sections: 
      Top  .................................................. 3¹⁄₂” (89 mm)
      Bottom ............................................. 1¹⁄₂” (38 mm)
      Sides ................................................ 2¹⁄₂” (64 mm)
  Vertical Vent Application: 
      Sides  ............................................... 1¹⁄₂” (38 mm)
A hearth is not mandatory but is recommended for  
aesthetic purposes. We recommend a noncombustible 
hearth which projects out 12” (305 mm) or more from 
the front of the fireplace. The hearth cannot exceed 1¹⁄₂” 
(38 mm) in height from bottom of fireplace for ease of 
door accessibility. (Fig. 4)
Cold climate installation recommendation:  
When installing this unit against a non-
insulated exterior wall or chase, it is 
mandatory the outer walls be insulated to 
conform to applicable insulation codes.  
Hearth
Clearance to Combustibles
Mantels
The height that a combustible mantel is fitted above the 
fireplace is dependent on the depth of the mantel. This 
also applies to the distance between the mantel leg (if 
fitted) and the fireplace.
For the correct mounting height and widths refer to 
Figs. 3a and 3b, the following Mantel Charts.
Noncombustible mantels and legs may be installed at 
any height and width around the appliance. 
When using paint or lacquer to finish the mantel, such 
paint or lacquer must be heat resistant to prevent 
discoloration.
�������
�������
������������
Fig. 3a  Combustible mantel minimum installation.
Mantel Chart
 
 
Mantel Shelf 
 
Mantel from Top
  Ref.  or Breast Plate  Ref.  of Comb. Chamber 
 
 
Depth
 
10”   (254 mm) 
10”   (254 mm)
 
9”  
(229 mm) 
9”   (229 mm)
 
8”  
(203 mm) 
8”   (203 mm)
 
7”  
(178 mm) 
7”   (178 mm)
 
6”  
(152 mm) 
6”   (152 mm)
CFM146d
Combustible 
Framing and  
Finish Wall Above 
Standoffs
Standoff
Top of Sheet Metal
Noncombustible Finish Material
(Such as Dura Rock)
Fireplace Front
May use com-
bustible facing 
material in this 
area
�������
���������������
�������
�������������
Mantel Leg
CFM164c
������
�����������������
����
�������������
CFM170a
Fig. 3b   Combustible mantel leg minimum installation.
 
 
Mantel 
 
Mantel Leg from Side
  Ref. 
Leg Depth 
Ref. 
of Comb. Opening
 
12”   (305 mm) 
12”   (305 mm)
 
9”   (229 mm) 
9”  
(229 mm)
 
6”   (152 mm) 
6”  
(152 mm)
 
4”   (102 mm) 
4”  
(102 mm)
 
3”   (76 mm) 
3”  
(76 mm)
Side of Fireplace
Noncombustible 
Finish Material