Vermont Casting DVT38S2 사용자 설명서

다운로드
페이지 40
7
Chateau™ Decorative Gas Appliance
20009543
Gas Inlet and Manifold Pressures
   
Natural  LP (Propane)
  Minimum Inlet Pressure 
5.5” w.c. 
11.0” w.c.
  Maximum Inlet Pressure  14.0” w.c. 
14.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
DVT38S2
Certified To
ANSI Z21.50b-2005 / CSA 2.22b-2005 
Vented Gas Fireplace
High Elevations
Input ratings are shown in BTU per hour and are 
certified without deration for elevations up to 
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA, 
installations must be in accordance with the 
current ANSI Z223.1/NFPA 54 and/or local codes 
having jurisdiction.
In Canada, please consult provincial and/or local 
authorities having jurisdiction for installations at 
elevations above 4,500 feet (1,370m).
WARNING:  Improper installation, adjust-
ment, alteration, service or maintenance 
can cause injury or property damage. Refer 
to this manual for correct installation and 
operational procedures. For assistance or 
additional information consult a qualified 
installer, service agency, or the gas supplier.
Gas Line Installation
When purging gas line the front glass must 
be removed.
A gas shut off valve must be installed on 
the gas pipe line going into the appliance 
within easy access.
The gas pipeline can be brought in through the bottom 
right side of the valve box assembly.    
The gas line connection can be made with properly 
tinned 1/2” copper tubing or 1/2” gas tight.  Some 
municipalities have additional local codes, it is always 
best to consult your local authority and the CSA-B149.1 
installation codes.
For USA installations consult the current National Fuel 
Gas Code, ANSI Z223.1/NFPA 54.
������
���������������
������������������
������
FP297A
1/2” Gas Supply
1/2” NPT X 1/2” Flare 
Shut-off Valve
1/2” Gas Tight or 
Tinned Copper 
(from valve)
(Not provided)
Fig. 8  Typical gas supply installation.
Final Finishing
Noncombustible materials such as brick or tile may be 
brought to the edges of the face of the appliance. 
������
�������
������
�������
������
���������������������
����������
FP1362
Fig. 7  Valve box framing.
  If marble, tile or any other noncombustible decora-
tive face finish material is desired, a 3” (76mm) wide 
noncombustible board (recommended Dura-Rock) 
is to be nailed to the nailing flanges on both sides 
of the unit. Also, 12” (305mm) of  noncombustible 
board is to be nailed to the front face of the U-chan-
nel and the top framing member above the standoff. 
  Combustible material can then be brought to the 
outside edges of the noncombustible board installed 
earlier. Any noncombustible decorative face finish 
could be brought to the sides and top of the unit and 
can cover the framing and sheet rock. If a decora-
tive facing is not desired, then the noncombustible 
boards must be double thickness and brought flush 
with the face of the unit.
Gas Specifications
 
 
 
 
MAX. 
MIN.
 
  
 
GAS 
 INPUT   INPUT
 
MODEL 
FUEL 
CONTROL 
B.T.U.H  B.T.U.H.
 DVT38S2RN  Natural Gas 
Millivolt 
56,000  38,000
  DVT38S2RP 
Propane 
Millivolt 
56,000  45,500
 DVT38S2EN  Natural Gas  24V Hi/Lo 
56,000  38,000
  DVT38S2EP 
Propane 
24V Hi/Lo 
56,000  45,500
DVT38S2 Units: GFSN6Q3, GFSE6Q3