wiring the fan
Attach the fan wires to the ceiling fixture outlet box wiring
by placing the bare ends of the wires together and then
securing with a wire nut.  Test that the connection is secure
by pulling on the wire nut.  Connect as follows:
GREEN leads from mounting plate and fan to
GROUND conductor of power source.  Secure with
wire nut.
WHITE wire from fan to white NEUTRAL wire in ceiling
fixture outlet box.  Secure with wire nut.
BLUE wire and BLACK power wire from fan to BLACK
power wire in ceiling outlet box.  Secure with wire nut.
WARNING:  Be sure no bare wires or wire strands
are visible after making connections
installing the canopy
1.
Tuck the wires into the outlet box with the wire nuts
pointed upwards, so that the WHITE and BLACK wires
are on opposite sides of the outlet box and all wires
are clear of the bracket opening.
2.
Loosen the 2 canopy screws in the mounting bracket.
Raise the canopy to the mounting bracket, assuring
that now wires are pinched, and pass the canopy
screws through the keyholes in the canopy.
3.
Rotate the canopy counter clockwise to engage the
keyholes.  Tighten the canopy screws firmly by hand
only.
removing the shipping blocks
On the motor, remove the five shipping blocks by
unscrewing the screws.  Set these screws aside for
installing the blades.
Discard the five shipping blocks.
installing the blades and blade
brackets
1.
Attach the blades to the blade bracket with the three
blade screws and flat washers provided for each blade.
Securely hand tighten the screws.
2.
Install the assembled blade and blade bracket to the
fan motor.  Securely hand tighten the screws.  Repeat
for each blade assembly.
operating the ceiling fan
1.
Turn on the electrical power to the fan.
2.
The fan pull chain controls the power to the fan.  The
pull chain has four settings in sequence: High,
Medium, Low, and Off.
NOTE:  Pull the chain slowly to change settings.
Release slowly to preven the chain from recoiling into
the blades.  The chain uses a breakaway connector
that separates if the chain is jerked.  If this happens,
simply reinsert the chain into the connector.
3.
To change the direction of air flow, turn the fan off and
let it come to a complete stop.  Slide the reversing
switch on the fan to the opposite position as.  Restart
the fan.
troubleshooting
Problem:  Nothing happens; fan does not move.
1.
Turn power on, replace fuse, or reset breaker.
2.
Loosen canopy, check all wiring connections according
to the wiring instructions.
3.
Push motor reversing switch firmly up or down to
ensure thta the switch is engaged.
4.
Pull the pull chain to ensure it is on.
5.
Remove the shipping bumpers.
Problem:  Noisy operation.
1.
Tighten the blade bracket screws until snug.
2.
Tighten the blade screws until snug.
3.
Check to see if the blade is cracked.  If so, replace all
the blades.
Problem:  Excessive wobbling.
1.
Tighten all blade and/or blade bracket screws.
2.
Turn power off, support fan very carefully, and check
that the hanger ball is properly seated.
Canopy
Canopy Screw
Shipping Blocks
Blade Screw
Flat Washer
Blade
Bracket
Screw
2 White
Wires
2 Green
Wires
2 Black
Wires
Blue Wire for Optional
Independent Light
Control (if used for this
reason, connect to the
light power wire from
the ceiling outlet box)