Pre-INstAllAtIoN PrePArAtIoN
Figure 3 - Minimum Clearances 
(Top View)
0"
0" Clearance
Nailing 
Flange
Front Face
Left Side 
Surround
Back
Drywall
2 x 4 Stud
Figure 4 - Minimum Clearances 
(Front View)
MANTEL CLEARANCES AND WALL 
DETAILS
A combustible mantle shelf maybe installed 
a  maximum  12"  (22.90  cm)  from  the  wall. 
Figures  5  and  6  show  the  minimum  allow-
able  distances  from  various  combustible 
mantle components in relation to the fireplace 
opening.
Figure 5 - Mantel Clearances - Side View 
(Cross Section)
Figure 6 - Side Clearances - Top View 
(Cross Section)
*
*
*
*
42" (10.67 cm)
Min. Clearance
from Opening to 
Ceiling
0" Clearance
Ceiling
1" (2.5 cm) Min.
Clearance to 
"B" Vent's Outer Pipe
Required
Air Spaces 
are Indicated 
with an "*".  
Do Not 
Pack with 
Insulation or 
Any Other 
Material
DO NOT BLOCK
OR OBSTRUCT
OPENINGS
0" Clearance 
to Wood or 
Noncombustible
Flooring
Spacer
3" (7.6 cm)
1
/
2
(3.8 cm) Max.
8" (20.3 cm)
6" (15.2 cm)
13" (33 cm)
12"
(22.9 cm)
Combustible
Materials
Header
1
/
2
" (3.8 cm)
Max.
3" (7.6 cm)
Max.
6" (15.2 cm)
Max.
9"
(22.86 cm)
12"
(30.48 cm)
Outer Surround
Combustible
Material May
Be Used
TOP VIEW
SAFE
ZONE
Perpendicular
Wall
CLEARANCES
Minimum clearances to combustibles are:
•  Top of Spacers 
0" min.
•  Back/Sides of Outer Surround 
0" min.
•  Drywall to Sides of Front Face
  (Nailing Flanges) 
0" min.
•  “B” Vent Surfaces 
1" min.
•  Ceiling to Opening 
42" min.
•  Floor 
0" min.
•  Perpendicular Wall 
See Figure 6
 CAUTION:  Do  not  block
required  air  spaces  with  insu-
lation or any other material. Do
not  obstruct  effective  opening
of  appliance  with  any  type  of
facing material.