FMI VP324E Manual Do Utilizador

Página de 32
www.fmiproducts.com
108794-01G
8
Pre-INstAllAtIoN PrePArAtIoN
Continued
FRAMING
1.  Frame appliance enclosure as illustrated 
in Figures 7 and 8.
 
Note:  If  a  wall  covering  is  used  to  line 
enclosure, then all measurements must 
be from surface of covering.
2.  Place appliance into framing and secure.
 
Note: If appliance is to be raised above 
floor  level,  a  platform  must  be  built  to 
support appliance.
3.  Install  supply  line  to  appliance  using  a 
1/2" NPT black iron gas line terminating 
5
/
16
" above bottom of appliance. The gas 
line must be installed through the lower 
left side access point or alternate access 
hole in bottom of appliance (see Figure 
16, page 12).
4.  Feed flexible gas line through one of three 
gas line conduit sleeves and repack insu-
lation to cover any openings. Prepare the 
incoming gas line with teflon tape or pipe 
joint compound and hook up incoming gas 
line to flexible gas line.
 
Note: If 1/2" NPT black iron pipe does not 
mate with fitting at end of flexible gas line, 
remove fitting and replace with a 37° flare 
3/4"-12, 1/2" NPT (female) fitting.
 WARNING:  When  finishing
appliance, do not overlap com-
bustible material onto the black
front face. Brick, tile or other non-
combustible  materials  may  be
applied to the face provided that 
any gap is between the material
used and the face is caulked with
a noncombustible caulking.
Figure 7 - Rough Opening for Installing 
in Wall
Figure 8 - Corner Installation Guidelines
16 
3
/
4
"
12"
39 
3
/
8
"
55 
5
/
8
"
34 
1
/
2
"
16"
These Dimensions Allow for a 3/4" 
Clearance at Sides and Back of Fireplace. 
However, 0" Clearance is Permitted
3/4" Clearance Not Required at 
Nailing Flanges 
VeNtING INstAllAtIoN
16 
1
/
8
"
34 
3
/
4
"
36 
5
/
8
"
A B-type venting system must be connected to 
appliance for venting to outside of building.
The following section is provided as a guide 
to a standard B-type vent installation.
Standing codes requirements concerning B-
type vent installations may vary within your 
state,  province  or  local  codes  jurisdiction. 
Therefore, it is recommended that you check 
with  your  local  building  codes  for  specific 
requirements or in absence of local codes, 
follow Section 7.0 of the current National Fuel 
Gas Code ANSI Z223.1/NFPA 54.
This  gas  appliance  must  be  vented  to  the 
outdoors only and may not be terminated into 
an attic space or into a chimney flue servicing 
a solid fuel burning appliance.