maintenance guide
52
Overheat 
Insuffi
  cient 
circulation
Water pressure
Bleed heat exchanger
Pump operation
CH return fi lter for blockages
Circulation around boiler (blockages)
ntc temperature sensors
Insuffi
  cient water 
(request fi lling)
Water pressure gauge for correct pressure
Check for waterleaks on the entire system
CH Flow temp.
probe circuit open/
short circuit
Check connections and wiring to temp 
sensors
CH Flow temp.
probe circuit open/
short circuit
Resistance values of temp sensors
Heating delivery 
probe problem
Details in maintenance guide in installation 
manual
Floor thermostat 
contact open
Check terminals TA2 for presence of link 
wire
EEPROM Error
Check the EEPROM connection onto the 
pcb
Communication 
error
Check connection and wiring onto all 
devices, main and display pcb
Main PCB error
Too many (>5) 
resets in 5 minutes
Identify reason for lockout from table and 
check for relevant faults
No Flame detected
Insuffi
  cient working gas  pressure
1st Ignition failed
Spark electrode/wiring connectors
2nd Ignition failed
Ignition electrode/wiring connectors
Flame cut-off 
Spark generator/wiring connectors
Check fl ue system for correct assembly/
termination
Check earth
Gas valve
CO2 settings
Soft light rate
Flame detected 
with gas valve 
closed
Ignition electrode/wiring connectors
Ignition electrode wiring connection onto 
main pcb
Flame lift
Insuffi
  cient working gas  pressure
Check fl ue system for correct assembly/
termination
CO2 settings
Thermofuse open
Check wiring and connections to 
thermofuse
Check integriry of main heat exchanger
Fan speed error
Check fan
Check wiring connections from fan to pcb
Fault fi nding