Ariston E-COMBI 24 30 38 Manual Do Utilizador

Página de 56
product description
7
E-COMBI
E-SYSTEM
   1.  Flue  connector
  2.  Manual air vent
 3. Burner
 4. Detection 
electrode
  5.  C.H. Return temperature probe
  6.  C.H. Flow temperature probe
 7. Gas 
valve
  8.  Secondary heat exchanger
 9. Trap
 10.  C.H. pressure relief valve
 11.  Electrical box
 12.  C.H. circuit fi lter
 13.  D.H.W. Flow switch
 14.  Circulation pump with auto air vent
 15.  Diverter valve
 16.  Low water pressure switch
 17.  Silencer (according to model)
 18.  Modulating fan
 19.  Ignition electrodes
 20.  Ignitor
 21.  Thermal fuse
 22.  Combustion analysis test point
Overall view
2
5
6
7
8
  9
10
11
22
21
20
19
18
17
15
16
14
12
13
1
2
3
4
5
6
7
9
10
11
22
21
20
19
18
17
14
16
12