Ariston 41-116-37 Manual Do Utilizador

Página de 72
25
installation
WARNING 
Before performing any work on the boiler, fi rst 
disconnect it from the electrical power supply using 
the external bipolar switch and remove the fuse.
Electrical connections
For increased safety, ask a qualifi ed technician to perform a 
thorough check of the electrical system. 
The manufacturer is not responsible for any damage caused by 
the lack of a suitable earthing system or by the malfunctioning of 
the electricity mains supply. 
Make sure that the system is able to withstand the maximum 
power absorbed by the boiler (this is indicated on the appliance 
data plate). Check that the section of the wires is suitable and is 
not less 0,75 mm
2
 
The appliance must be connected to an effi
  ecient earthing system 
if it is to operate correctly.
The power supply cable must be connected to a 230V-50Hz 
network, where the L-N poles and the earth connection are all 
respected.
 Important!
In the event that the power supply cable must be changed, 
replace it with one with the same specifi cations.
Power supply cable
Important!
The appliance is supplied with a fl y-lead  already 
connected, this must be connected to a 240V supply 
fused at 3 Amp and must facilitate completed 
electrical isolation of the appliance, by use of a fused 
double pole isolator having a contact separation of at 
least 3mm in all poles or alternatively by means of a 3A 
fused three pin plug and unswitched shuttered socket 
outlet both complying with BS1363.
The use of multiplugs, extension leads or adaptors is strictly 
prohibited. 
It is strictly forbidden to use the piping from the hydraulic, heating 
and gas systems for the appliance earthing connection. 
The boiler is not protected against the eff ects caused by lightning. 
If the mains fuses need to be replaced, use 2A rapid fuses.
Peripheral unit connection
To access peripheral unit connections carry out the following 
steps:
 -   Disconnect the boiler from the power supply
 -   Remove the casing by unhooking it from the instrument panel
 -   Rotate the control panel while pulling it forwards
 -   Unhook the two clips “a”, rotate the cover “b” to have access to 
the peripherical connections
 -   Unscrew the two screws “c” and remove the cover “d” of the 
instrument panel to have access to the main P.C.B.
H05V2V2-F
60
N
L
a
b
c
d
BUS
T
B
TA2
SE
TNK
SOL
TA1
BUS
T
B
TA2
FLOOR
SE
TNK
SOL
TA1
CN1
Remote Control
Outdoor sensor
Underfloor heating
thermostat
Room Thermostat 2
Room Thermostat 1
Peripheral connections:
BUS = Remote control connection
FLOOR/TA2 = the underfl oor heating thermostat or the room 
thermostat 2 (selected via parameter 223)
SE =   the external sensor.
SOL =   Solar temperature probe
TA1 =   the room thermostat 1