DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-544
DISK (MSS Disk Circuit Pack) 
9
run. MTC (maintenance busy) means that the device is busied out; users cannot 
access it, but all demand maintenance tests run. OUT (out of service) means that 
users cannot access the device, but background and demand testing may run.
Notes:
a. Error type 1 means that the device is out of service as a result of 
maintenance tests detecting a critical failure of the disk drive.
b. Error type 18 means that the disk was busied out on demand from the 
System Access Terminal.
c. Error type 250 means that the Reset Test (#809 or #894) failed.
d. Error type 257 means that the device could not be accessed.
e. Error type 258 means an attempt was made to remove a disk that was 
physically present or failure during remove occurred.
f. Error type 513 means that on-board disk drive diagnostics tests requested 
by the Disk Diagnostic Test (#813) failed.
g. Error type 526 means that the Host Adapter was busied out. This also 
causes the disk to be busied out.
h. Error type 528 means that there was a failure to insert the disk at system 
initialization time. This is a software problem. 
i. Error type 529 means that there was a failure to put the disk in service or to 
take it out of service. Execute the reset disk command and then execute 
the status spe command to verify that the disk is in service. If the disk is 
not in the expected state, first clear any other alarms against other MSS 
components and then execute the reset disk command. 
j. Error type 769 means that the disk Loop-around Test (#814) failed.
k. Error type 1025 means that a disk medium error was detected when the 
disk was read or written. The Disk circuit pack should be replaced if this 
error continues to be reported.
l. Error type 1281 indicates that a hardware failure condition was detected 
by the Firmware Error Counters Read and Clear Test (#812). See the 
Error Actions table at the end of the section on TAPE.
m. Error type 1793 is an in-line error from the disk control software that 
indicates there was a problem with the SCSI Bus Access Failure or 
Memory Access Failure between the Host Adapter and the Disk Drive. See 
the 
MSS Error Actions table at the end of the section on TAPE.
n. Error type 2049 indicates that a bad command was sent to the disk drive. 
This may be caused by a software error or a hardware failure. Execute the 
test disk long command and fix any failures associated with those tests. 
Error type 2305 means that the system is equipped with more than 2 
memory circuit packs and the disk is either not large enough or has not 
been configured correctly to support the larger memory size.