Lucent Technologies Release 7 Manual Do Utilizador

Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-546
DISK (MSS Disk Circuit Pack) 
9
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Disk 
Reset Test, for example, you may also clear errors generated from other tests in 
the testing sequence.
Disk Reset Test (#809 and #894)
The Disk Reset Test consists of the following steps controlled by firmware on the 
Host Adapter Circuit (located on the MSSNET circuit pack):
Disk Drive reset: A SCSI BUS DEVICE RESET message is transmitted to 
the Disk circuit pack to reset it.
Presence test: A SCSI INQUIRY command is sent to the Disk Drive to 
attempt to query it. If the Disk Drive is present, it will return information 
about the device type, whether or not its medium is removable, 
compatibility with established standards, vendor and product IDs, and 
other miscellaneous information.
Start unit: This starts the disk drive spinning.
Capacity test: A SCSI READ CAPACITY command is sent to the Disk 
Drive. It returns with the logical block address and the block length of the 
last logical block on the medium. This is necessary to restore the 
information lost after the reset and verify that the device can be accessed.
A SCSI READ DATA BUFFERS command is sent to the Disk Drive. This 
returns the size of the controller memory data buffers.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Reset Board 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Disk Reset Test (#809)
X
X
ND
Disk Diagnostic Test (#813)
X
X
ND
Disk Looparound Test (#814)
X
X
ND
Disk Status Test (#815)
X
X
ND
Disk Firmware Error Counters 
Read and Clear Test (#812)
X
X
ND
Disk Write-Read Test (#810)
X
ND
Disk Audit Test (#811)
X
ND
Disk Reset Test (#894)
X
ND