Lucent Technologies Release 7 Manual Do Utilizador

Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1085
MODEM-PT (Modem Pool Port) 
9
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Modem Pool Conference Test, for example, you may also clear errors generated 
from other tests in the testing sequence.
NOTE:
The tests in this section do not apply to Combined Modem Pool conversion 
resources. The standard Digital Line and/or Analog Line port tests are run 
on the ports associated with the Combined Modem Pool. Consult the test 
descriptions for those maintenance objects when repairing Combined 
Modem Pool arrangements.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive, ND = Non-destructive
Modem Pool NPE Crosstalk Test (#96)
X
D
Modem Pool Conference Test (#97)
X
D
Modem Pool Conversion Resource 
Looparound Test (#98)
X
X
ND
Modem Pool Audits Test (#99)
X
X
ND