Maintenance Object Repair Procedures 
9-1086
MODEM-PT (Modem Pool Port) 
9
Modem Pool NPE Crosstalk Test (#96)
This test is destructive.
The Modem Pool Crosstalk Test verifies that the NPE is connected only to the 
desired time slot and is not crosstalking on other time slots. This test operates 
exactly like Test #6 for other types of port circuits but is performed twice in order 
to test both NPEs in the Modem Pool Port
Table 9-431.
TEST #96 Modem Pool NPE Crosstalk Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required for this test are not available. The port may be in use 
on a valid call. Determine if the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under 
heavy traffic conditions or it may have time slots out-of-service due to TDM-BUS 
errors. 
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat the test at 1-minute intervals a maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be 
oversized for the number of Tone Detectors present or some Tone Detectors 
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals a maximum of 5 
times.
1004
ABORT
The port has been seized by a user for a valid call. Determine whether the port 
is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1020
ABORT
The test did not run due to a previously existing error on the specific port or 
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit pack, 
and attempt to diagnose the previously existing errors.
2000
ABORT
A response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.