DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Architecture 
1-8
How to use the Maintenance book 
1
8. Note the Error Type (
Err Type
 field) value (1547) and the 
Aux Data
 
value if present.
9. Find the DID-TRK MO in the Maintenance Object chapter of the 
appropriate maintenance book.
10. In the first table look up the initial command to run in the MAJOR row of the 
table (Step 4 indicated that a DID trunk in slot 10, carrier C has a MAJOR 
alarm).
11. Type test port 01C1008 long and press 
Enter
.
“01C1008” is the address of the alarmed port (see 
12. While the port test is running, look up the Error Type (1537 from 
) in the DID Trunk Error Log Entries table (example below).
13. Since the Test to Clear Value (
test port 01C1008 sh r 1) is very similar to the 
initial test you ran in Step 11, wait for the results of the port test.
14. When the port test finishes, the following display appears (
Screen 1-4
):
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs), C is the carrier designation (A, B, 
C, D, or E), 
SS is the number of the slot in which the circuit pack resides (01 to 21), and pp is the 
two digit port number (01, 02, ...).
Full Name of MO
DID-TRK
MAJOR
2
2.
A MAJOR alarm on a truk indicates that alarms on these trunks are downgraded by the set options 
command and that at least 75% of the trunks in this trunk group are alarmed.
test port UUCSSpp long
DID Trunk
DID-TRK
MINOR
test port UUCSSpp long
DID Trunk
DID-TRK
WARNING
test port UUCSSpp
DID Trunk
Table 1-2. DID Trunk Error Log entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1537
Port Diagnostic 
(#35)
MAJ/MIN/
WRN
OFF
test port UUCSSpp sh r 1
3840 (k)
40965
None
Continued on next page