Maintenance Architecture
1-10
Maintenance Objects
1
Maintenance Objects
The system is partitioned into separate entities called maintenance objects
(MOs). Each MO is monitored by the system and has its own maintenance
strategy. Most MOs are individual circuit packs such as the processor circuit
pack (PROC) and expansion interface circuit pack (EXP-INTF). Some are
hardware components that reside on part of a circuit pack. For example, the TDM
bus clock (TDM-CLK) and tone generator (TONE-PT) circuits reside on the
tone/clock circuit pack (TONE-BD). Others represent larger subsystems or sets
of monitors, such as expansion port network (EXP-PN) and cabinet
environmental sensors (CABINET).
(MOs). Each MO is monitored by the system and has its own maintenance
strategy. Most MOs are individual circuit packs such as the processor circuit
pack (PROC) and expansion interface circuit pack (EXP-INTF). Some are
hardware components that reside on part of a circuit pack. For example, the TDM
bus clock (TDM-CLK) and tone generator (TONE-PT) circuits reside on the
tone/clock circuit pack (TONE-BD). Others represent larger subsystems or sets
of monitors, such as expansion port network (EXP-PN) and cabinet
environmental sensors (CABINET).
Finally, some MOs represent processes or combinations of processes and
hardware, such as synchronization (SYNC) and duplicated port network
connectivity (PNC-DUP). The above abbreviations are
hardware, such as synchronization (SYNC) and duplicated port network
connectivity (PNC-DUP). The above abbreviations are
maintenance names as
recorded in the error and alarm logs. Individual copies of a given MO are further
Cabinet
Enter cabinet number (1 - 44)
Port Network
Enter port network number (1 - 44)
Board Number
Enter 5-character board number in UUCSS format:
cabinet (1-44), carrier (A-E), slot (0-20)
cabinet (1-44), carrier (A-E), slot (0-20)
Port
Enter 7-character port address in UUCSSss format:
cabinet (1-44), carrier (A-E), slot (0-20), circuit
(01-31)
cabinet (1-44), carrier (A-E), slot (0-20), circuit
(01-31)
Category
Enter category name (choose 1 from the list below:
adm-conn
announce
bri/asai
cdr
data-mod
detector
dup-spe
environ
exp-intf
ext-dev
generatr
inads-link
infc
maint
mass-st
mbus
memory
misc
mmi
mnt-test
modem
mssnet
pkt
pms/jrnl
pnc
pncmaint
pnc-peer
procr
quick-st
s-syn
spe
stabd
stacrk
stations
sys-link
sys-prnt
tape
tdm
tone
trkbd
trkcrk
trunks
vc
vsp
wideband
wireless
Extension
Enter assigned extension, or blank
Trunk
Group
Enter group number between 1-666
Member
Enter group member between 1-255, or blank