Lucent Technologies Release 6 Manual Do Utilizador

Página de 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-90
Add DS1 Tie and OPS 
5
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press 
Enter 
to verify that the system is in the “active/standby” mode.
2. Enter save translation. Press 
Enter
. This instructs the system to take all 
translation information in memory and write it to the translation card or 
tape.
3. If the system contains a TN750/B Announcement circuit pack, enter 
display announcements and press 
Enter
. If administered recorded 
announcements are listed, enter list configuration software-version 
press 
Enter.
 Check Page 2 of this form to see when the announcements 
were last saved. To save the current announcements, enter save 
announcements
 and press 
Enter.
Shut Down DEFINITY LAN Gateway System
!
WARNING:
Neglecting to shut down a DEFINITY LAN Gateway assembly before powering down 
the system cabinet where it resides can damage the LAN Gateway disk.
!
CAUTION:
Save the system parameters if you plan to reuse the current system.
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select 
Maintenance.
3. Select 
Reset System
 from the 
Maintenance
 menu.
4. Select 
Shutdown
 from the 
Reset System
 menu.
Shut Down DEFINITY AUDIX System
!
WARNING:
Neglecting to shut down an AUDIX assembly before powering down the system 
cabinet where it resides can damage the AUDIX disk.
1. If a DEFINITY AUDIX resides in the system to be upgraded, shut down the 
AUDIX assembly and allow the disk to completely spin down.