Lucent Technologies Release 6 Manual Do Utilizador

Página de 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-92
Add DS1 Tie and OPS 
5
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press 
Enter
 to verify that the system is in the “active/standby” mode.
2. Enter save translation and press 
Enter
. This instructs the system to take all 
translation information in memory and write it to the translation card or 
tape.
3. If the PPN contains a TN750 Announcement circuit pack, enter list 
configuration software-version and press 
Enter.
If Page 2 of this form shows that recorded announcements were saved, 
these announcements can be restored using the restore announcements 
command. Enter restore announcements and press 
Enter
.
Enable Customer Options
1. Enter change system-parameters customer-options and press 
Enter
.
2. Use these forms to verify the customer options are properly set.
NOTE:
In the 
Basic Call Setup 
field, if 
ISDN-PRI?
 was set to 
y
 before the 
upgrade, be sure to set the field back to y.
Resolve Alarms
Examine the alarm log. Resolve any alarms that may exist using 
DEFINITY 
Enterprise Communications Server Release 6 Maintenance R6vs/si
Contact INADS to Enable Customer Options and
Verify Alarm Origination
Be sure the system is part of the existing INADS database by calling the INADS 
Database Administrator at the Technical Service Center (TSC). Verify that INADS 
can dial into the system and that the system can dial out to INADS. 
As part of the system registration process, the INADS Database Administrator 
enables Alarm Origination and enables customer options.