Test Telephones and Other Equipment 
Page 6-5
Test Basic Rate Interface 
6
Local Test
1. Log in and enter the test inads-link command.
2. Request remote access personnel to verify a trouble ticket was created.
3. Check error log to verify no problems.
4. Log off the system.
Test Basic Rate Interface
Check for normal voice telephone function (dial tone, ability to make and receive 
calls). Check for the correct Service Profile Identifier (SPID) on a display 
telephone and the management terminal.
Test Duplication Option Processing
Element Interchange
The process of the standby Processing Element (PE) taking over for the active PE 
is referred to as a PE Interchange. This interchange should not be performed 
immediately after powering up the system. Wait a few minutes to allow the system 
to complete its internal tests. The system default is 
PE_B
 after powering up the 
system, so the active PE should be the B processor for this test, and the 
interchange should make 
PE_A
 the active PE. Verify the system can successfully 
perform a PE interchange.
1. At the management terminal, verify the screen displays 
PE_B
 in the upper 
right corner.
2. Enter check status command. Verify 
PE_B
 is in the standby mode. If it is, 
proceed to Step 4. If it is not, proceed to Step 3.
3. Enter refresh-spr-standby command.
4. Enter reset system interchange command. The management terminal 
will be logged off and a beep will be heard.
5. Login and verify that the screen displays 
PE_A
 in the upper right corner.
NOTE:
Processor A’s yellow light is on and its green LED is off. Processor 
B’s yellow and green LEDs are off. The system is alarm free.
6. Make system test call. The call must complete and the conversation must 
be satisfactory.