Test Telephones and Other Equipment 
Page 6-6
Test Terminating Trunk Transmission 
6
Test Terminating Trunk Transmission 
The Terminating Trunk Transmission Test provides for extension number access 
to 3 tone sequences that can be used for trunk transmission testing from the 
distant end of the trunks.
The 3 test types must have extension numbers assigned on the 
system-parameters maintenance form:
Test Type 100:_______ 
Test Type 102:_______
Test Type 105:_______
Test type 100 provides:
5.5 Seconds of 1004 Hz tone at 0 dB
Quiet until disconnect; disconnect is forced after 1 minute
Test Type 102 provides:
9 Seconds of 1004 Hz tone at 0 dB
1 Second of silence
Cycle is repeated until disconnect, which is forced after 24 hours
Test Type 105 provides:
9 Seconds of 1004 Hz tone at -16 dB
1 Second of silence
9 Seconds of 404 Hz tone at -16 dB
1 Second of silence
9 Seconds of 2804 Hz tone at -16 dB
30 Seconds of silence
0.5 Seconds of test progress tone (2225 Hz)
Approximately 5 seconds of silence
Forced disconnect