Lucent Technologies Release 6 Manual Do Utilizador

Página de 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Connecting Fiber Optic Cables 
Page A-2
LASER Product 
A
LASER Product
The DEFINITY ECS may contain a Class 1 LASER device if single-mode fiber 
optic cable is connected to a remote Expansion Port Network (EPN). The LASER 
device operates within the following parameters:
Maximum Power Output: -5dBm
Wavelength: 1310 nm
Mode Field Diameter: 8.8 microns
CLASS 1 LASER PRODUCT
IEC 825 1993
!
CAUTION:
Use of controls or adjustments or performance of procedures other than 
those specified herein may result in hazardous radiation exposure.
Contact your Lucent Technologies representative for more information.
Fiber Optic Requirements
If estimated fiber losses are suspected of exceeding loss limits due to excessive 
length, splices, and so forth, perform OTDR (Optical Time Domain 
Reflectometer) or Optical Power Meter tests to ensure a successful installation of 
a remote EPN fiber link.
The requirements that determine the maximum fiber optic cabling distances are:
The mean loss and the length of the outside plant fiber cable
The mean loss and the length of fiber cable shipped with the cabinet 
(including any fiber riser cable)
The mean loss of an ST connector and the number of ST connections
The mean loss due to the total number of splices
Higher-order mode loss