Lucent Technologies Release 6 Manual Do Utilizador

Página de 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Connecting Fiber Optic Cables 
Page A-3
Fiber Optic Requirements 
A
Fiber Optic Cable Connections
The Customer Service Document (CSD) provides an “Inter-Carrier Cable 
Running List.” Each row on the list represents a cable connection. Use the 
running list to determine where to connect each fiber optic cable.
Multi-Mode Fiber Optic Connections
Multi-mode fiber cables are generally colored gray or orange. The following 
components are used in multi-mode fiber optic connections:
Expansion Interface (EI) circuit packs in port slots in cabinet carriers
Switch Node Interface (SNI) circuit packs in the Switch Node Carrier
The 9823A lightwave transceiver transmits up to 4,900 feet (1500 m). The 
9823B lightwave transceiver transmits up to 25,000 feet (7600 m).
Multi-mode fiber optic cable consisting of 2 separate 62.5 micron or 50 
micron core fiber optic cables.
Single-Mode Fiber Optic Connections
!
CAUTION:
Do not use Dispersion Shifted or Wave Diversion Multiplexing fiber. Use 
only dispersion unshifted fiber such as Depressed Clad and Matched Clad 
fiber (EIA/TIA Class IVa).
Single-mode fiber cables are generally colored yellow. The following components 
are used in single-mode fiber optic connections:
Expansion Interface (EI) circuit packs in port slots in cabinet carriers
Switch Node Interface (SNI) circuit packs in the Switch Node Carrier
The 300A lightwave transceivers. Each 300A transmits light up to 115,000 
feet or 22 miles (35 km). Fiber loss must be less than 17dB. Saturation 
may occur if distances are short; attenuators may be required if the total 
loss on the fiber link is less than 10dBm. An OTDR or Optical Power Meter 
test is recommended to determine specific fiber optic hardware 
requirements.
NOTE:
Using the 300A may require 5, 10, or 15dB attenuators. Se
. Also, contact 
your Lucent Technologies representative for attenuator requirements 
on single-mode links.
Single-mode fiber optic cable consisting of 2 separate 8 to 10 micron core 
cables.