Datalogic Scanning I GD4100 Manual Do Utilizador

Página de 324
General Features
42
Gryphon™ I GD4100
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state once the state is 
entered. The range for this setting is from 1 to 255 seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 
= 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming 
Mode.
4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING.
5. Scan the appropriate three digits from the keypad in 
Appendix E, Keypad
, that represent the 
duration which was determined in the steps above. You will hear a two-beep indication 
after the last character.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming 
Mode.
This completes the procedure. See Table
4
 for some examples of how to set this feature.
Table 4. Scanning Active Time Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
1 Second
90 Sec. (1.5 min.)
180 Sec. (3 min.)
255 Seconds (4.25 min.)
2
Pad leading zero(es)
001
090
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT SCANNING ACTIVE TIME SETTING
5
Scan Three Characters 
From 
Appendix E, Keypad
‘0’, ‘0’ and ‘1’
‘0’, ‘9’ and ‘0’
‘1’, ‘8’ and ‘0’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL 
barcode to abort and not save the entry string. You can then start 
again at the beginning.