Datalogic Scanning I GD4100 Manual Do Utilizador

Página de 324
General Features
44
Gryphon™ I GD4100
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable 
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with 
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming 
Mode.
4. Scan the barcode: SELECT FLASH ON TIME SETTING.
5. Scan the appropriate two digits from the keypad in 
Appendix E, Keypad
 representing the 
duration which was determined in the steps above. You will hear a two-beep indication 
after the last character.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming 
Mode.
This completes the procedure. See Table
5
 for some examples of how to set this feature.
Table 5. Flash On Time Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1,000ms (1 sec.)
5200ms (5.2 sec.)
9,900ms (9.9 sec.)
2
Divide by 100 (and pad 
with leading zeroes to yield 
two digits)
05
10
52
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH OFF TIME SETTING
5
Scan Two Characters From 
Appendix E, Keypad
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
 ‘9’ and ‘9’
6
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL 
barcode to abort and not save the entry string. You can then start 
again at the beginning.