Installation 
4-10 C156-E228-02EN 
The access supervision time from the host is about 33 minutes as the default.  
However, it can be changed by the MODE SELECT command. 
The spindle auto stop mode can also be changed by the MODE SELECT 
command. 
Table 4.5 shows spindle auto stop mode setting. 
Table 4.5  Spindle automatic stop mode setting 
Spindle auto stop 
SW1-07 
The spindle motor automatically stops. 
ON (*1) 
The spindle motor does not automatically stop. 
OFF 
*1 
Setting when shipped 
 
The characteristic of the spindle auto stop function are as follows: 
• 
Reduces the deposition of dust which could cause a cartridge error. 
• 
Not suitable for a system requiring quick response because it takes a 
few seconds to start the spindle. 
4.3.2  Setting of supplying power to SCSI terminating resistor 
Table 4.6 shows how to supply power to the SCSI terminating resistor module on 
the drive and how to use TERMPWR lines on the SCSI bus.  
Table 4.6  SCSI terminating resistor power supply (CNH1) 
SCSI terminating resistor power supply 
CNH1 01-02 
CNH1 03-04 
Power is supplied from both of the drive and 
TERMPWR pin. 
Short (*1) 
Short (*1) 
Power is supplied from the drive only. 
(TERMPWR pin is not used)  
Short Open 
Power is supplied from TEMPWR pin only. 
(Drive’s power supply is not used) 
Open Short 
No power is supplied. 
Open 
Open 
*1 
Setting when shipped