Fujitsu MCM3130SS Manual Do Utilizador

Página de 170
Installation 
4-12 C156-E228-02EN 
4.4  Mounting 
4.4.1  Checks before mounting the drive 
Before mounting the optical disk drive in the system cabinet, check whether the 
setting switches and terminals are set correctly. 
Table 4.8 shows the checklist. 
Table 4.8  Setting checklist 
  
Setting 
item 
Setting 
on: 
Default 
Check 
 1 SCSI 
ID 
 
SW1-01 
SW1-02 
SW1-03 
 
OFF 
OFF 
OFF 
(SCSI ID=    ) 
o
OFF    
o
ON 
o
OFF    
o
ON 
o
OFF    
o
ON 
 
2  SCSI data bus parity check 
SW1-04 
ON 
o
OFF    
o
ON 
 3 Write 
cache 
mode 
SW1-05  OFF 
o
OFF    
o
ON 
 4 Device 
type 
mode 
SW1-06  ON 
o
OFF    
o
ON 
 
5  Spindle automatic stop mode 
SW1-07 
ON 
o
OFF    
o
ON 
S
ett
ing sw
it
ch 
 6 Factory 
test 
mode 
(user setting inhibited) 
SW1-08 OFF 
o
OFF    
o
ON 
 
  
Setting 
item 
Setting 
on: 
Default 
Check 
 
1  Supplied from both ODD and 
TERMPWR pin. 
CNH1  1-2 
CNH1  3-4 
Short 
Short 
o
Short   
o
Open 
o
Short   
o
Open 
 
2  Supplied from ODD 
CNH1  1-2 
CNH1  3-4 
Short 
Short 
o
Short   
o
Open 
o
Short   
o
Open 
CNH1 
 
3  Supplied from TERMPWR pin. 
CNH1  1-2 
CNH1  3-4 
Short 
Short 
o
Short   
o
Open 
o
Short   
o
Open 
 
  
Check 
item 
Check 
 
1  Drive location on SCSI bus 
o
Other 
o
Either 
    than end      end 
Term
ina
ti
ng 
res
ist
or 
 
2  SCSI terminating resistor mode (CNH1 5-6) 
 
o
Open 
o
Short