7.2  Sense Data Analysis 
C141-E198 
7-3 
7.2 
Sense Data Analysis 
7.2.1 
Error information indicated with sense data 
 
Subsection 7.2.2 onwards explain troubleshooting using sense data. 
 
Table 7.1 lists the definition of sense data.  For details of sense data, refer to the Fibre Channel 
Interface Specifications. 
Table 7.1 
Definition of sense data 
Sense data 
 
Sense 
key 
Sense 
Code 
Sub 
Sense 
Code 
 
00 00 00 
Operation 
was 
normal. 
0C 
03 
A write to a disk terminated abnormally. 
4 32 
40 
44 
C4 
01 
xx 
xx 
xx 
Failed to update the defect list due to a disk medium write error, etc. 
An error occurred in power-on self-diagnosis. 
A hardware error occurred inside IDD. 
A drive error occurred. 

1x 
1x 
xx 
xx 
A disk read error occurred. 
A disk read error occurred. 
1D 
00 
Data discrepancy found by VERIFY command byte check. 
2x 
xx 
A SCSI error, such as an invalid operation code, occurred. 
 
3D 
00 
The Reserve bit of the IDENTIFY message was set to 1. 
47 
00 
A CRC error occurred in the fibre channel loop. 
49 
00 
An unmounted or inappropriate message was received. 
4D 
xx 
Before completion of a command, a command with the same tag 
number was issued. 
4E 
00 
An overlap command was issued. 
 
Definition