Freescale Semiconductor MC68HC908MR32 Manual Do Utilizador

Página de 282
Timer Interface A (TIMA)
MC68HC908MR32 • MC68HC908MR16 Data Sheet, Rev. 6.1
224
Freescale Semiconductor
4.
In TIMA channel x status and control register (TSCx):
a.
Write 0:1 (for unbuffered output compare or PWM signals) or 1:0 (for buffered output compare 
or PWM signals) to the mode select bits, MSxB–MSxA. (See 
b.
Write 1 to the toggle-on-overflow bit, TOVx.
c.
Write 1:0 (polarity 1 — to clear output on compare) or 1:1 (polarity 0 — to set output on 
compare) to the edge/level select bits, ELSxB–ELSxA. The output action on compare must 
force the output to the complement of the pulse width level. (See 
.)
NOTE
In PWM signal generation, do not program the PWM channel to toggle on 
output compare. Toggling on output compare prevents reliable 0 percent 
duty cycle generation and removes the ability of the channel to self-correct 
in the event of software error or noise. Toggling on output compare can also 
cause incorrect PWM signal generation when changing the PWM pulse 
width to a new, much larger value.
5.
In the TIMA status control register (TASC), clear the TIMA stop bit, TSTOP.
Setting MS0B links channels 0 and 1 and configures them for buffered PWM operation. The TIMA 
channel 0 registers (TACH0H–TACH0L) initially control the buffered PWM output. TIMA status control 
register 0 (TASC0) controls and monitors the PWM signal from the linked channels. MS0B takes priority 
over MS0A.
Setting MS2B links channels 2 and 3 and configures them for buffered PWM operation. The TIMA 
channel 2 registers (TACH2H–TACH2L) initially control the buffered PWM output. TIMA status control 
register 2 (TASC2) controls and monitors the PWM signal from the linked channels. MS2B takes priority 
over MS2A.
Clearing the toggle-on-overflow bit, TOVx, inhibits output toggles on TIMA overflows. Subsequent output 
compares try to force the output to a state it is already in and have no effect. The result is a 0 percent duty 
cycle output.
Setting the channel x maximum duty cycle bit (CHxMAX) and setting the TOVx bit generates a 100 
percent duty cycle output. (See 
16.4  Interrupts
These TIMA sources can generate interrupt requests:
TIMA overflow flag (TOF) — The timer overflow flag (TOF) bit is set when the TIMA counter 
reaches the modulo value programmed in the TIMA counter modulo registers. The TIMA overflow 
interrupt enable bit, TOIE, enables TIMA overflow interrupt requests. TOF and TOIE are in the 
TIMA status and control registers.
TIMA channel flags (CH3F–CH0F) — The CHxF bit is set when an input capture or output compare 
occurs on channel x. Channel x TIMA CPU interrupt requests are controlled by the channel x 
interrupt enable bit, CHxIE. 
16.5  Wait Mode
The WAIT instruction puts the MCU in low power-consumption standby mode.