SMSC LAN9514 Manual Do Utilizador

Página de 47
USB Hub with Integrated 10/100 Ethernet Controller 
Datasheet
SMSC LAN9514
39
Revision 1.0 (04-20-09)
DATASHEET
 
Chapter 4 Operational Characteristics
4.1
  Absolute Maximum Ratings*
Supply Voltage (VDD33IO, VDD33A) (
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0V to +3.6V
Positive voltage on signal pins, with respect to ground (
). . . . . . . . . . . . . . . . . . . . . . . . . . +6V 
Negative voltage on signal pins, with respect to ground (
) . . . . . . . . . . . . . . . . . . . . . . . . -0.5V
Positive voltage on XI, with respect to ground  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+4.6V
Positive voltage on XO, with respect to ground  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+2.5V
Ambient Operating Temperature in Still Air (T
A
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  0
o
C to +70
o
C
Storage Temperature  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  .-55
o
C to +150
o
C
Lead Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Refer to JEDEC Spec. J-STD-020
HBM ESD Performance per JESD 22-A114-E  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+/- 8kV
Contact Discharge ESD Performance per IEC61000-4-2 (
)  . . . . . . . . . . . . . . . . . . . . . .+/- 8kV
Air-Gap Discharge ESD Performance per IEC61000-4-2 (
 . . . . . . . . . . . . . . . . . . . . .+/- 15kV
Latch-up Performance per EIA/JESD 78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  .+/- 200mA
Note 4.1
When powering this device from laboratory or system power supplies, it is important that
the absolute maximum ratings not be exceeded or device failure can result. Some power
supplies exhibit voltage spikes on their outputs when AC power is switched on or off. In
addition, voltage transients on the AC power line may appear on the DC output. If this
possibility exists, it is suggested that a clamp circuit be used.
Note 4.2
This rating does not apply to the following pins: XI, XO, EXRES, USBRBIAS.
Note 4.3
This rating does not apply to the following pins: EXRES, USBRBIAS.
Note 4.4
Performed by independant 3rd party test facility.
*Stresses exceeding those listed in this section could cause permanent damage to the device. This is
a stress rating only. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability. Functional operation of the device at any condition exceeding those indicated in
, or any other applicable section
of this specification is not implied. Note, device signals are NOT 5 volt tolerant unless specified
otherwise.
4.2
  Operating Conditions**
Supply Voltage (VDD33A, VDD33BIAS, VDD33IO)  . . . . . . . . . . . . . . . . . . . . . . . . . . .+3.3V +/- 300mV
Ambient Operating Temperature in Still Air (T
A
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  0
o
C to +70
o
C
**Proper operation of LAN9514 is guaranteed only within the ranges specified in this section.