Fujitsu fi-5120C Manual Do Utilizador

Página de 28
2
■ Removable Parts
Parts that can be removed from the scanner are dis-
played below.
1.3 Operator Panel
The operator panel is located on the right side of the 
scanner. This panel comprises  of a Function Number 
display, four buttons and a LED.
*) About the settings on the launcher, refer to FUJITSU 
TWAIN32 scanner driver help and the "fi-5120C/fi-
5220Cfi-5120C/fi-5220C Operator’s Guide" in the Setup 
CD-ROM.
■ Indications on the Function 
Number Display
Pad ASSY
ADF paper chute
Pick roller
Sheet guide
Document cover
Can be
removed
[fi-5220C only]
Function  
Number 
display
Function
Send to
Scan
LED
Power button
Name
Function
Function Number display
Indicates the function Num-
ber and error status.
Buttons
Function
Changes the Function acti-
vated by the Send to button 
(*).
Send to
Launches the linked applica-
tion software (*).
Scan
Power button
Turns the scanner ON and 
OFF.
LED
-
Lights when the scanner is 
turned ON.
No.
Descriptions
8
Lights only one time upon turning on the scanner.
P
Indicates that the scanner has been turned ON and 
is being initialized.
0
Indicates that initialization will soon be completed.
1
Indicates that initialization has been completed 
successfully.
This status is called "Ready Status". 
U
Indicates that a temporary error occurred when 
documents were being scanned. A number appear-
ing in alternation following the U  (i.e., 1 or 2, etc.) 
refers to the type of error.
To return the scanner to the ready status ("1"), 
press "Scan" or "Send to" button.
E
Indicates that a device (hardware) alarm has 
occurred during scanning of documents.
"E" and the alarm Number (0 to 9, A,c,d and F) 
will appear alternately.
To return the scanner to the ready status ("1"), 
press "Scan" or "Send to" button.
If this alarm occurs, turn the power off and on 
again. If the alarm continues after turning the 
power on again, contact your service engineer.