• When drilling, make sure you do not accidentally damage any power lines, gas
pipes or water pipes.
• Install the alarm system with suitable mounting material (use the screws included
in the delivery if required).
7. Connection
After successful device installation, 
you can now start to connect it. Careful-
ly take off the connection terminal cov-
er. It is attached with two screws. After
successful connection, replace the cov-
er and re-attach the attachment screws
removed first.
The voltage required for operation is 12-16V/DC at the terminal clamps
7 (-) and 8 (+).
Observe correct polarity in order not to damage the product!
We recommend to additionally connect a 12V, 1.2Ah lead battery to
maintain operation in case of a power outage. 
For this, observe the connection example in chapter: „7.8“!
Activate the operational voltage only after completing all connections.
7.1 Alarm Zones 1 and 2
Notes:
N.O (Normally open - contacts, sensors with open contacts - closed in
case of alarm)
N.C (Normally closed - contacts, sensors with closed  contacts - open
in case of alarm)
In both alarm zones, sensors with N.C. and N.O. contacts can be used.
28