4.4.9
F100 ST – Self Test Status
Use Self Test Status to query the status of the power-up tests.  The response contains the 
PASS/FAIL status of the flash memory checksum test, RAM test, Utility Port test, and 
version check.
To query the self-test status, send the following command:
F100<SP>ST<Enter>
where:
F
=
ASCII character F
100
=
unit function number
<SP>
=
space
ST
=
specify ST command
<Enter>
=
input line terminator
The unit responds:
F100<SP>ST<SP>FLASH/CRC<SP>:<SP><STATUS>,<SP>RAM<SP>:
<SP><STATUS>,<SP>SERIAL<SP>:<SP><STATUS>,<SP>VER<SP>:
<SP><STATUS><CR><LF>
where:
F
=
ASCII character F
100
=
unit function number
<SP>
=
space
ST
=
specify ST command
FLASH/CRC
=
specify flash checksum result
RAM
=
specify RAM test result
SERIAL
=
specify Utility Port test result.
VER
=
specify version test result.  This test compares the 
version of the code against the version recorded in  
Non-Volatile memory
<STATUS>
=
is either ASCII PASS or FAIL
,
=
ASCII  comma
:
=
ASCII  colon
<CR><LF>
=
output line terminator
An example of the response is:
F100 ST flash/CRC : PASS, Ram : PASS, Serial : PASS, Ver : 
PASS<CR><LF>