Symmetricom Time Server Manual Do Utilizador

Página de 148
4-66
TimeVault™ User’s Manual
6000-100Ch4.fm  Rev. D
Chapter 4: Serial or Telnet I/O Functions
Extended Function Commands
4.4.10
F100 VER – Software Version Request
Use Version Request to obtain the software version number of the unit.  The version 
number is set at compile time, and cannot be changed.  It may only be queried.
To query the version number send the following command:
F100<SP>VER<Enter>
where:
F
=
ASCII character F
100
=
unit function number
<SP>
=
space
VER
=
specify Version Request command
<Enter>
=
input line terminator
An example of the response is:
>f100 VER
f100 VER
 BOOTLOADER  182-9006v008
 SOFTWARE    182-9007v008
 FILE SYSTEM 182-9008v008
 NVRAM VER   2
4.4.11
F100 T – Current Time Source Request 
Use Current Time Source Request to know which time source TimeVault is currently 
using.
To query the current time source, send the following command:
F100<SP>T<Enter>
where:
F
=
ASCII character F
100
=
TimeVault function number
<SP>
=
space
T
=
specify Current Time Source Request command
<Enter>
=
input line terminator
An example of the response is:
F100 T GPS <CR><LF>