Initial configuration
The AdderView CATxIP 5000 unit provides an initial configuration  
sequence to assist you to make the necessary settings. 
When the AdderView CATxIP 5000 is switched on for the first time, you 
should see the unit configuration screen, as shown here 
 
IMPORTANT: Complete the initial IP configuration and invoke security 
measures BEFORE the unit is connected to an open IP network.
If the AdderView CATxIP 5000 unit has been previously configured,  
it will display either the Login dialog or the Select Host screen,  
as shown here 
 
Admin password
Enter a password of at least six characters that has a mix of letters 
and numerals. The background colour provides an indication of 
password suitability and is initially red to indicate that the password is 
not sufficient. When a password with reasonable strength has been 
entered it will change to green. 
Time and Date
Set these correctly as all entries in the activity log are time stamped 
using them.
Encryption
See 
 for a description of the issues and the settings.
UseDHCP/IP address/Net Mask/Gateway
You need to either set the DHCP option to ‘Yes’ or manually enter a 
valid IP address, Net mask and Gateway. See 
 for 
more details.
VNC and HTTP ports
These should remain set to 5900 and 80, respectively, unless they 
clash with an existing setup within the network. See 
 for more details.
Option port (serial) details
These two items control the use of the OPTIONS port on the rear 
panel of the unit. The port can either be used to control optional 
power switching devices or can be used to synchronise the operation 
of two separate AdderView CATxIP 5000 units.
If neither of these features are required, then you do not need to 
change anything on this screen.  
Secure keys generation
With every mouse move and keypress, the single dash will move 
across the screen (unless the same key is pressed repeatedly). 
Periodically, a new star character will be added to the bar as the 
random data are accepted as part of the new encryption key. When 
the bar is full, the final encryption keys for your AdderView CATxIP 
5000 will be created – this process takes roughly 30 to 40 seconds. 
Once the secure keys have been calculated the AdderView CATxIP 
5000 will show either the Login dialog or Select Host screen.
Note: Screen 5 of 5 is displayed while 
the secure keys are being generated.
   



 
 
 



 







 

   
   
 
 
 
 

 
 







   
   
 
 
 


   
   
   
    
  
   
    
    
 

  


   


      
  
  



 
 
 
 
 
 
 
 









If the Login is shown, enter 
your ‘admin’ Username and 
Password - or press 
 twice if 
none have yet been defined. 
From the Select Host screen, 
press   to display the Main 
Menu. See 
more details.  
   

 
 
 


Within the Main Menu, use the 
 and   keys to highlight an 
option, then press 
 to select.
The Configuration option 
provides access to separate 
Unit, Network and Serial 
Configuration screens that are 
similar in function to the first 
three setup screens shown on 
the right.