Delta Tau GEO BRICK LV Manual Do Utilizador

Página de 271
Geo Brick LV User Manual
 
PinOuts and Software Setup 
 49 
Encoder Loss Detection, Quadrature 
Designed for use with differential line-driver outputs (encoders), the encoder loss circuitry monitors each 
quadrature  input  pair  with  an  exclusive-or  XOR  gate.  In  normal  operation  mode,  the  two  quadrature 
inputs should be in opposite logical states – that is one high and one low – yielding a true output from the 
XOR gate. 
 
 
Note 
Single-Ended Quadrature Encoders are not supported for encoder loss. 
 
Ch#  Address/Definition    Ch#  Address/Definition     
 
Y:$78807,0,1 
 
Y:$78807,4,1 
  Status Bit  Definition 
Y:$78807,1,1 
 
Y:$78807,5,1 
  =0 
Encoder lost, Fault 
Y:$78807,2,1 
 
Y:$78807,6,1 
  =1 
Encoder present, no Fault 
Y:$78807,3,1 
 
Y:$78807,7,1 
   
 
 
!
Caution 
Appropriate  action  (user-written  plc)  needs  to  be  implemented  when 
an  encoder  loss  is  encountered.  To  avoid  a  runaway,  an  immediate 
Kill of the motor/encoder in question is strongly advised.   
 
No  automatic  firmware  (Geo  Brick)  action  is  taken  upon  detection  of  encoder(s)  loss;  it  is  the  user’s 
responsibility  to  perform  the  necessary  action  to  make  the  application  safe  under  these  conditions,  see 
example  PLC  below.  Killing  the  motor/encoder  in  question  is  the  safest  action  possible,  and  strongly 
recommended  to  avoid  a  runaway,  and  machine  damage.  Also,  the  user  should  decide  the  action  to  be 
taken (if any) for the other motors in the system. The Encoder Loss Status bit is a low true logic. It is set 
to 1 under normal conditions, and set to 0 when a fault (encoder loss) is encountered.