Vertex Standard FT-950 Manual Do Utilizador

Página de 137
 
FT-950 
Operating Manual 
Vertex Standard Co., Ltd. 
109
Menu Mode 
The Menu system of the FT-950 provides extensive customization capability, so you can 
set up your transceiver just the way you want to operate it. The Menu items are 
grouped by general utilization category, and are numbered from “001 AGC FST DLY” to 
“118 TGEN EMRGNCY”. 
 
Using the Menu 
1.  Press the [MENU] button momentarily, to engage the Menu mode. 
The display will show the Menu Number, Menu Group Name, and Menu Item. 
Press the [SELECT] knob to toggle the display between “Menu Number & Menu 
Group Name” and “Menu Item”. The Multi-Display Window shows the current 
setting of the currently-selected Menu item. 
2.  Rotate the [SELECT] knob to select the Menu item you wish to work on. 
3.  Rotate the [CLAR/VFO-B] knob to change the current setting of the selected Menu 
item. 
4.  When you have finished making your adjustments, press and hold in the [MENU] 
button for two seconds to save the new setting and exit to normal operation. If you 
only 
momentarily
 press the [MENU] button, the new settings will 
not
 be retained. 
 
Menu Mode Reset 
You may reset all the Menu settings to their original factory defaults, if desired. 
1.  Turn the front panel [POWER] switch off. 
2.  Press and hold in the [MENU] button, and while holding it in, press the [POWER] 
switch to turn the transceiver back on. Now release the [MENU] button. 
 
AGC Group 
001 AGC FST DLY 
Function: Sets the delay time for the AGC FAST mode. 
Available Values: 20 ~ 4000 msec (20 msec/step) 
Default Setting: 300 msec 
 
002 AGC MID DLY 
Function: Sets the delay time for the AGC MID mode. 
Available Values: 20 ~ 4000 msec (20 msec/step) 
Default Setting: 700 msec