Vertex Standard FT-950 Manual Do Utilizador

Página de 137
 
FT-950 
Operating Manual 
Vertex Standard Co., Ltd. 
110
003 AGC SLW DLY 
Function: Sets the delay time for the AGC SLOW mode. 
Available Values: 20 ~ 4000 msec (20 msec/step) 
Default Setting: 3000 msec 
 
 
DISPLAY Group 
004 DISP COLOR 
Function: Selects the Display color when the optional Data Management Unit 
(DMU-2000) is connected. 
Available Values: bL1/bL2/bL3/ub1/ub2 
bL1: COOL BLUE 
bL2: CONTRAST BLUE 
bL3: FLASH WHITE 
ub1: CONTRAST UMBER 
ub2: UMBER 
Default Setting: bL1 (COOL BLUE) 
Advice: If the optional DMU-2000 Data Management Unit is not connected, this 
adjustment has no effect. 
 
005 DISP DIM VFD 
Function: Setting of the display brightness level. 
Available Values: 0 ~ 7 
Default Setting: 4 
 
006 DISP BAR SEL 
Function: Selects one of three parameters to be viewed on the Tuning Offset Indicator. 
Available Values: CLAr/C-tn/u-tn 
Default Setting: C-tn 
CLAr:  Displays relative clarifier offset. 
C-tu:  Displays relative tuning offset between the incoming signal and transmitted 
frequency while CW operation. 
u-tn:  Displays the peak position of the optional µ-TUNE filter. 
 
007 DISP PKH S 
Function: Selects the peak hold time of the S-meter.