Vertex Standard FT-950 Manual Do Utilizador

Página de 137
 
FT-950 
Operating Manual 
Vertex Standard Co., Ltd. 
121
MODE-FM Group 
056 F3E MIC 
Function: Sets the microphone gain for the FM mode. 
Available Values: Ur/0 ~ 100 
Default Setting: 50 
When this menu is set to “Ur,” you may adjust the microphone gain using the front 
panel’s [MIC GAIN] knob. 
 
057 F3E 28 RPT 
Function: Sets the magnitude of the repeater shift on the 28 MHz band. 
Available Values: 0 ~ 1000 kHz 
Default Setting: 100 kHz 
 
058 F3E 50 RPT 
Function: Sets the magnitude of the repeater shift on the 50 MHz band. 
Available Values: 0 ~ 4000 kHz 
Default Setting: 1000 kHz 
 
 
MODE-RTY Group 
059 RTTY R PLRTY 
Function: Selects normal or reverse Mark/Space polarity for RTTY receive operation. 
Available Values: nor/rEV 
Default Setting: nor 
 
060 RTTY T PLRTY 
Function: Selects normal or reverse Mark/Space polarity for RTTY transmit operation. 
Available Values: nor/rEV 
Default Setting: nor 
 
061 RTTY OUT LVL 
Function: Sets the RTTY (AFSK) data output level at the output port (pin ?) of the 
RTTY/PKT jack. 
Available Values: 0 ~ 100 
Default Setting: 50