GE JGSP44 Manual Do Utilizador

Página de 38
8
1. Install a manual shut-off valve in the gas
supply line in an easily accessible location.
2. Know how and where to shut off the gas
supply to the range.
3. Shut off gas supply before removing an old
range.  Leave it off until hookup of new range
is finished.
4. Because solid pipe restricts moving the
range, we recommend use of an A.G.A.
certified metal appliance connector.
NEVER REUSE AN OLD CONNECTOR WHEN
INSTALLING A NEW RANGE.
WARNING: 
Never reuse old flexible
connectors.  The use of old flexible
connectors can cause gas leaks and
personal injury.  Always use new flexible
connectors when installing a gas appliance.
5. Before making gas connections, make sure
that the oven shut-off lever (visible at the back
of range) is in the open position.
6. Install 1/2" flare union adaptor to the 1/2" NPT
elbow on pressure regulator.
7. Connect flexible appliance connector to flare
union.
8. Move range into approximate position and
connect flexible connector to gas supply line
with proper flare union adaptor.
  9. To prevent gas leaks, put a pipe joint sealant
on all male threads.
10. When you are finished making connections,
be sure that all range knobs are turned to
OFF before you open the main gas supply
valve.
Gas Connections
Installation Instructions
D1
D
Making the Connections
25"
5"
2 1/2"
7"
2 1/2"
5 1/2"
12 1/2"
1 1/2"
18"
7"
Recommended area for 120V outlet on rear 
wall and aea for through the wall connection
 of pipe stub and shut-off valve
Recommended area for
through the floor connection 
of pipe stub and shut-off valve
Anti-Tip location
Gas Inlet
Shut-Off Lever
Shown in the 
Open Position
Gas Supply
to Oven
Gas Supply to 
Top Burner
Pressure Regulator
as see from  Front  of 
Range
Flex 
Connector
Flair Unions
Pressure
Regulator
90˚ Street Elbow
Shut-Off
Valve
Gas Supply
Line