3.4 Gain Control Mode (AGC/MGC)
 
 
Automatic gain control (AGC): 
 
AGC/MGC switch is located on the rear plate. 
AGC factory setting is 2V for AGC control and 3V for AGC MAX control.  Therefore, the maximum gain is about 
18dB as shown in Figure 6 below.   AGC setting cannot be changed through the rear gain potentiometer. 
 
Manual gain control (MGC): 
 
The manual gain control can be adjusted from 5dB to 18dB through the gain potentiometer on rear plate.  
 
Note: 32dB gain can be obtained through custom orders. 
 
 
 
Figure 6. AGC and AGC MAX Control Characteristics 
 
 
3.5 Gamma 1.0 and 0.45 Mode 
 
1.0/0.45 mode switch is located on rear plate.  Gamma is the numerical value of the degree of contrast in a 
television picture. Gamma correction is the system response modification by providing linear transfer 
characteristic from the input to output.  In general, circuit built into a TV camera to compensate for non-linearity 
that exists in display tubes.  If the camera is connected directly to a frame grabber, it is desired to set to Gamma 
1.0.  For direct connection to a TV monitor, gamma 0.45 is recommended, since TV monitor has a non-linear 
correction.  In general, gamma 0.45 is noisier than gamma 1.0, which is why gamma 1.0 is chosen for machine 
vision applications.  Gamma 0.45 is preferred when seeing video at low light level, which is common for 
inspection by human eyes. 
 
 
 
 