Справочник Пользователя для Regency P33-LP4

Скачать
Страница из 52
Regency
®
 P33-4 Zero Clearance Direct Vent Gas Fireplace
7
DUCT SYSTEM OPTION
kit #946-556
The  HeatWave Air Duct Kit increases the 
effectiveness of your fi replace by dispersing 
warm air from the fi replace to remote locations 
in the same room or other rooms in your 
home. 
Up to  two kits may be installed on the fi replace. 
Please Note: Only 1 HeatWave kit may be 
operated at one time. This includes the internal  
blower option as well. 
INSTALLATION 
CHECKLIST
1)  Locate appliance
 a) 
Room 
location
 
 
(Refer to "Locating Your Fireplace" 
Section)
 
b)  Clearances to Combustibles
 
 
(Refer to "Clearances" Section)
 c) 
Mantle 
Clearances
 
 
(Refer to "Combustible Mantels" 
Section)
 
d)  Framing & Finishing Requirements 
(Refer to "Framing & Finishing" 
Section)
 e) 
Venting 
Requirements
 
 
(Refer to "Venting" Sections)
2)  Assemble Top Facing Support and Side 
Nailing Strips (Refer to "Unit  Assembly Prior 
to Installation" Section).  NOTE: Must be 
done before installing unit into fi replace.
3)  Install vent (Refer to "Venting" Sections)
4)  Make gas and electrical connections. Test 
the pilot. Must be as per diagram.
 
(Refer to "Gas Line Installation" and "Pilot 
Adjustment" Section). 
 
Convert to Propane if desired.
 
(Refer to "Conversion Kit from NG to LPG" 
Section).
5)  Install standard and optional features. Refer 
to the following sections:
 
a.  Optional Brick Panels
 
b.  Log Set Installation
 c. 
Standard 
Flush 
Door
 d. 
Optional 
Flush 
Trim
 
e.  Double Screen Door
 
f.  Optional Bay Door
 g. 
Optional 
Bay 
Trim
 h. 
Flush 
Louvers
 
i.   Bay Louvers
 j. 
Full 
Screen 
Doors
 k. 
 
Optional 
Wall 
Themostat
 
l.  Optional Remote Control
 
m.  Optional Wall Switch
 
n.  Installing the Optional Fan
6) Final 
check.
Before leaving this unit with the customer, 
the installer must ensure that the appliance is 
fi ring correctly and operation fully explained 
to customer
.
This includes:
1)  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label) after burning 
appliance for 15 minutes.
2)  If required, adjusting the primary air to ensure 
that the fl ame does not carbon. First allow 
the unit to burn for 15-20 min. to stabilize.
Diagram 1
INSTALLATION
CAUTION: Any alteration to the product that 
causes sooting or carboning that results 
in damage is not the responsibility of the 
manufacturer.
LOCATING YOUR 
FIREPLACE
1)  When selecting a location for your fi replace, 
ensure that the clearances outlined on this 
page are met.
2)  P r o v i d e   a d e q u a t e   c l e a r a n c e s   f o r 
servicing.
3)  The appliance must be installed on a fl at, 
solid, continuous surface (e.g. wood, metal, 
concrete). This may be the fl oor, or raised up 
on a platform to enhance its visual impact. 
If the appliance is going to be installed 
on carpeting, combustible linoleum tile or 
other combustible material other than wood 
fl ooring, the appliance must be installed on a 
metal or wood panel extending the full width 
and depth of the appliance.
UNIT DIMENSIONS
4)  The P33-4 can be installed in a recessed 
position or framed out into the room as in 
A, B, C, D. See Diagram 1 below.
5)  This appliance is Listed for bedroom 
 
installations when used with a Listed 
Millivolt Thermostat. Some areas may 
have further requirements, check local 
codes before installation.
6)  The P33-4 Direct Vent Gas Fireplace 
is approved for alcove installations, 
which meet the clearances listed on the 
"Clearances" Section.
7)  We recommend that you plan your 
installation on paper using exact 
measurements for clearances and fl oor 
protection before actually installing this 
appliance. Have a qualifi ed inspector, 
dealer, or installer review your plans before 
installation.
Note:   For vent terminations see "Exterior 
Vent Termination Locations" Section.
A) 
Flat on Wall
B) 
Flat on Wall Corner
C) Recessed 
into 
Wall/Alcove