Справочник Пользователя для Honeywell T7350

Скачать
Страница из 40
T7350 COMMERCIAL PROGRAMMABLE THERMOSTAT
63-2548—5
2
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or 
phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, 
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
FEATURES
 (continued from page 1)
Features Available via PDA Configuration
• 365 day clock with holiday programming.
• Automatic Daylight Saving Time adjustments.
• Selectable dehumidification limit control.
• Modulating output configuration.
• Occupancy input to control standby setpoint.
• Additional standby period used in low traffic areas.
• Sequential start option.
• Discharge air high/low limits.
• Selectable recovery ramp.
• Ambient lockout (with outdoor sensor).
• System monitoring.
• Application database with download and storing.
Features via Optional Network Model-H
• Communications on LonTalk
®
 network.
• Network Tools (LonSpec, CARE) have ability to 
configure all PDA available features.
• T7350 Network data inputs including outdoor air 
temperature, Occupancy Sensor, Electric Demand 
Shed/Restore, room temperature and humidity.
• Use T7350H to time-schedule up to 119 network 
connected XL10 + XL15c devices.
• Time synchronization with a network master clock or 
the T7350H configured as the network master clock.
• Remote manual occupancy changes to the T7350 via 
Command Display (S7760).
• View and modify weekly schedules and holidays via 
Command Display (S7760).
• Remote changes to the T7350 occupancy override, 
schedules, fan operation (on auto), system mode (off, 
auto, heat, cool) and room temperature setpoints via 
Workstation.
• Remote unoccupied bypass controlled from another 
device.
• Remote T7350 data and alarm monitoring via 
Command Display or Workstation.
• Network Manual Mode allows a remote user to turn on/
off or modulate each output via a network connection.
•  LonMark plugin software to facilitate third party 
configuration tools and workstations.