Справочник Пользователя для American Water Heater VGD625T 100

Скачать
Страница из 60
23
CONDENSATE PIPING
This water heater is a condensing unit and requires a drain to be 
located in close proximity to allow the condensate to drain safely. 
The condensate drains from the unit at the exhaust tee located at 
the bottom of the unit (see Figure 11). Condensate from this water 
heater is mildly acidic. Please note that some local codes require 
that condensate is treated by using a pH neutralizing filter prior to 
disposal.
Caution must be used to ensure that the drain is free and clear of 
debris and will not allow backflow through the condensate hose. 
Consideration must be given to avoid freezing of the condensate 
lines which could result in excessive build up of condensate inside 
the  water  heater.  Waterproof  heat  tape  may  be  required  to  prevent 
freezing of the condensate lines. Please ensure that the outlet of the 
condensate drain does not create a slippery condition which could 
lead to personal injury.
Condensation warning: this water heater is a condensing unit and 
requires a drain to be located in close proximity to allow condensate 
to drain safely. The condensate drains from unit at the exhaust elbow 
located at bottom of unit. Note: it is important that the condensate 
hose  not  be  elevated  above  the  exhaust  elbow,  see  Figure  11. 
Condensate build-up will block the exhaust outlet, which will cause 
improper operation.
Figure: 11
The condensate drain line must be routed to a suitable drain. If 
no  floor  drain  is  available  or  the  drain  is  above  the  level  of  the 
condensate  line,  install  a  condensate  pump  that  is  resistant 
to  the  acidic  condensate.  These  pumps  are  available  from 
local  distributors.  If  the  pump  is  not  resistant  to  acidic  water,  a 
condensate neutralizer must be used ahead of the pump. When 
installing the drain line, note the following:
•  Plastic pipe or tubing must be used to connect the condensate 
drain to a suitable drain or condensate pump. Do not use copper 
tubing, iron, or steel pipe for the condensate drain line.
•  Condensate drain lines should be installed in conditioned areas 
only. Drain lines installed in areas that are subject to freezing 
temperatures should be wrapped with a nationally recognized/
listed heat tape and/or approved insulation for freeze protection. 
Install per manufacturer’s instructions.
•  Do not common drain with the temperature and pressure relief 
valve or the condensate line from an air conditioner evaporator 
coil.
•  Slope  the  condensate  drain  toward  the  inside  floor  drain  or 
condensate pump.
•  The condensate drain line and connection to the drain piping 
must comply with all local codes.
HIGH ALTITUDE INSTALLATIONS
This  high  efficiency  water  heater  is  certified  for  use  without 
modification for an altitude of 10,100 feet (3,078 m). Consult the 
factory for installation at altitudes over 10,100 feet (3,078 m).
Some gas utility companies derate their gas for altitude, making it 
unnecessary to install high altitude orifices. Call the local gas or 
utility company to verify BTU content.
Due to the input rate reduction at high altitudes, the output rating 
of the water heater is also reduced and should be compensated 
for in the sizing of the equipment for applications.
FILLING THE WATER HEATER
Never use this water heater unless it is completely full of water. 
To prevent damage to the tank, the tank must be filled with water. 
Water must flow from the hot water faucet before turning ON gas 
to the water heater.
To fill the water heater with water:
1.  Close the water heater drain valve by turning the handle to the 
right (clockwise). The drain valve is on the lower front of the 
water heater.
2.  Open  the  cold  water  supply  valve  to  the  water  heater. 
 
NOTE: The cold water supply valve must be left open when the 
water heater is in use.
3.  To insure complete filling of the tank, allow air to exit by opening 
the nearest hot water faucet. Allow water to run until a constant 
flow is obtained. This will let air out of the water heater and the 
piping.
4.  Check  all  water  piping  and  connections  for  leaks.  Repair  as 
needed.
Exhaust 
Elbow