Never use this water heater unless it is completely filled with water.  
To prevent damage to the tank, the tank must be filled with water. 
Water must flow from the hot water faucet before turning “ON” gas 
to the water heater.
A   *Condensation may be seen on pipes in humid weather or pipe 
connections may be leaking.
B.  *The anode rod fitting may be leaking.
C.  Small amounts of water from temperature-pressure relief valve 
may be due to thermal expansion or high water pressure in your 
area.
D.  *The  temperature-pressure  relief  valve  may  be  leaking  at  the 
tank fitting.
E.  Water from a drain valve may be due to the valve being slightly 
opened.
F.  *The drain valve may be leaking at the tank fitting.
G.  Leakage from recirculation plug or pipe connection.
H.  Leakage from the plug under the cleanout cover.
I.  Leakage from the temperature probe connection (Not shown in 
figure).
J.  Condensate from the exhaust connection.
Leakage from other water heaters, water lines, or ground seepage 
should also be checked.
*  To  check  where  threaded  portion  enters  tank,  insert  cotton 
swab between jacket opening and fitting. If cotton is wet, follow 
“Draining” instructions in the “Periodic Maintenance” section and 
then remove fitting. Put pipe dope or teflon tape on the threads 
and replace. Then follow “Filling the Water Heater” instructions 
in the “Installing the New Water Heater” section.
LEAKAGE CHECKPOINTS
Figure: 38
A:Inlet & 
Outlet
B:Anode 
Rod 
Connection
G:Recirculation
Connection
C:T & P 
Connection
D:T & P Outlet
G:Recirculation
Connection
J:Flue Outlet
F:Drain Valve 
Connection
H:Cleanout
E:Drain 
Valve