Справочник Пользователя для Mitsubishi Electronics MR-J2S- CP

Скачать
Страница из 357
 
 
11 -  1 
11. TROUBLESHOOTING 
 
11. TROUBLESHOOTING 
11.1 Trouble at start-up 
CAUTION 
Excessive adjustment or change of parameter setting must not be made as it will 
make operation instable. 
 
POINT 
 
Using the MR Configurator (servo configuration software), you can refer to 
unrotated servo motor reasons, etc. 
 
The following faults may occur at start-up. If any of such faults occurs, take the corresponding action. 
No. 
Start-up sequence 
Fault 
Investigation 
Possible cause 
Reference 
Not improved if connectors 
CN1A, CN1B, CN2 and CN3 
are disconnected. 
1. Power supply voltage fault 
2. Servo amplifier is faulty. 
Improved when connectors 
CN1A and CN1B are 
disconnected. 
Power supply of CN1 cabling is 
shorted. 
Improved when connector 
CN2 is disconnected. 
1. Power supply of encoder 
cabling is shorted. 
2. Encoder is faulty. 
LED is not lit. 
LED flickers. 
Improved when connector 
CN3 is disconnected. 
Power supply of CN3 cabling is 
shorted. 
 
1 Power 
on 
Alarm occurs. 
Refer to section 11.2 and remove cause. 
Section 11.2 
Alarm occurs. 
Refer to section 11.2 and remove cause. 
Section 11.2 
2 Switch 
on 
servo-on 
signal. 
Servo motor shaft is 
not servo-locked 
(is free). 
1. Check the display to see if 
the servo amplifier is 
ready to operate. 
2. Check the external I/O 
signal indication to see if 
the servo-on (SON) signal 
is ON. 
1. Servo-on signal is not input. 
(Wiring mistake) 
2. 24VDC power is not 
supplied to COM. 
Section 7.3.2 
Rotation ripples 
(speed fluctuations) 
are large at low 
speed. 
Make gain adjustment in the 
following procedure. 
1. Increase the auto tuning 
response level. 
2. Repeat acceleration and 
deceleration several times 
to complete auto tuning. 
Gain adjustment fault 
Chapter 7 
3 Gain 
adjustment 
Large load inertia 
moment causes the 
servo motor shaft to 
oscillate side to side. 
If the servo motor may be 
run with safety, repeat 
acceleration and 
deceleration several times to 
complete auto tuning. 
Gain adjustment fault 
Chapter 7 
Cyclic operation 
Position shift occurs  Confirm the cumulative 
command pulses, cumulative 
feedback pulses and actual 
servo motor position. 
Pulse counting error, etc. 
due to noise.